Burn-in with online-monitoring

Temperature and climatic test


Mechanical test

Product Qualification and Environmental Tests

product qualification = advanced long-time reliability = minimization of failure costs

We perform customer specific qualifications and according to standards like AEC-Q 100/101/200, ESCC 9020/9010, MIL-STD 883/202, JEDEC 020, TELCORDIA GR 468/1221/326/1312, IEC 60 068-2-XX and DIN.

  • definition of test concept and qualification plans
  • life-test, burn-in and run-in
  • HAST (highly accellerated stress test) and pressure cooker
  • environmental test, ESD test
  • (opto)electronical characterization
  • physical layout analysis
  • solderability tests and solder profile qualification
  • RoHS-compliance, e.g. definition and check of moisture sensitivity level (MSL)

Environmental Simulation and Accelerated Aging

climatic tests:

  • -70 °C up to +300 °C and between 10% and 98% relative humidity (constant/ cyclic/ shock)
  • pressure cooker and HAST

mechanical tests:

  • shock, vibration (sinus/ random) and bump